Engineered Medium Voltage Starter Products
Smart Full Voltage ATL Starters
Highlights:
The “Smart” Medium Voltage “ATL” package includes the addition of
the RediStart MX
3
control package for additional branch circuit moni-
toring motor protection, metering, diagnostics and communication.
Refer to MVRMX RediStart MX
3
specification for complete details.
A sampling of the enhanced features includes:
Protection (ANSI standard numbers given)
• 51 - Electronic motor overload, class 1 to 40
• 86 - Overload lockout
• 59/27 - Adjustable over/under voltage protection
• 46 - Adjustable line to average current imbalance
• 81 - Adjustable high and low frequency protection
• Single phase protection
• 66 - Adjustable starts per hour (off or 1 to 20 starts)
• Adjustable time between starts (off or 1 to 600 minutes)
• Backspin timer (off or 1 to 200 minutes)
• 51 - Overcurrent detection (off or 50 to 800%) and time
(0.1 to 90.0 sec. in 0.1 sec. intervals)
• 37 - Undercurrent detection (off or 10 to 100% and time
(0.1 to 90.0 sec. in 0.1 sec. intervals)
• 51G - Ground fault detection (off or 1 to 100 amps) and
time (0.1 to 90.0 sec. in 0.1 sec. intervals)
• Overcurrent, undercurrent, and ground fault can each be
set to trip or activate a relay
• 50 - Instantaneous electronic overcurrent trip
• 47 - Phase rotation selectable ABC, CBA, or Ins
(insensitive)
• 38/49 - Remote mountable RTD protection package, 8 or
16 RTD inputs (optional)
Control
• Local start/stop controls
• Emergency reset capability
Input/Output and Display
• Plain English operation via back lit LCD display interface
• LCD and LED status and diagnostics (full fault
annunciation)
• Programmable metering (amps, volts, frequency,
overload, power factor, elapsed time, watts, VARs,
watt hours, VA, current imbalance, ground fault current,
RTD temperatures with optional RTD module)
• Programmable relay outputs
• Latched fault relay output
• Real time clock
• Time stamped event recorder
• Password protection
• Battery backed-up starter parameters and lockout times